Evaluation of maximum inspiratory pressure with the SERIOUS GAME “I BLUE IT” using the MANO-BD device
DOI:
https://doi.org/10.62827/fb.v27i3.1161Keywords:
Respiratory Function Tests; Maximal Respiratory Pressures; Physiotherapy.Abstract
Introduction: Serious Games (SG) are digital games created with a specific purpose. In the health area, SG play a significant role due to its ability to be customized according to patients’ needs. Given this universe of new therapeutic and functional assessment possibilities, the SG I Blue It (IBI) stands out as a biomedical system for potential assessment of maximum inspiratory pressure (MIP) and use in respiratory rehabilitation. Objective: To evaluate the applicability of the IBI in the assessment of MIP. Methods: This is a descriptive study, with 30 healthy individuals included in the research, 6 men and 24 women with a mean age of 26.13 ± 7.92 years. Ninety concurrent measurements of MIP were performed using the SG IBI and an analog manometer. Continuous variables were analyzed using mean and standard deviation, and comparison and correlation between the means obtained by the IBI devices and the analog manometer were performed using Student's t-test (p<0.05) and Pearson's correlation coefficient. Results: The mean MIP obtained by the analog manometer was lower than that of the IBI, with a difference of 4.09 cmH2O, but did not present statistical significance (p=0.429) and there was a strong correlation between the variables (r=0.808). Conclusion: The results observed suggest that the analog manometer devices used and the Mano-BD present concurrent MIP measurements, and it is possible to infer that the IBI biomedical system with the Mano-BD device can be applied to assess MIP in the sample evaluated.
References
Grimes HR, Hounseel SM. Sistema biomédico com jogo sério e dispositivo especial para reabilitação respiratória. [monografia]. Joinville (SC): Universidade do Estado de Santa Catarina; 2019.
Santos MA, Grimes HR, Hounsell SM, Noveletto F, Soares VA, Silva EH. I Blue It: um jogo sério para auxiliar na reabilitação respiratória. In: SBGames; 2018; Foz do Iguaçu (PR): 179-188.
Henrique MAY, Hounsell SM, Néry CTJ. Complexidade de sensoriamento para jogos sérios do tipo exergame para a área da saúde. In: SBGames; 2020; Recife (PE): 1064-1067.
ATS/ERS Statement on Respiratory Muscle Testing. Am J Respir Crit Care Med. 2002 Aug 15;166(4):518–624. doi:10.1164/rccm.166.4.518.
Santos RM. Manovacuometria realizada por meio de traqueias de diferentes comprimentos. Fisioter Pesq. 2017;24(1):9-14. doi:10.1590/1809-2950/15614124012017.
Naso DCF, Pereira SJ, Schuh JS, Unis G. Avaliação funcional em pacientes com sequela pulmonar de tuberculose. Rev Port Pneumol. 2011;7(5):216-221. doi:10.1016/j.rppneu.2011.06.010.
Green M, Road J, Sieck GC, Similowski T. Tests of respiratory muscle strenght. Am J Respir Crit Care Med. 2002;166:528-47.
I Blue It [Internet]. [cited 2024]. Available from: https://udescmove2learn.wordpress.com/2018/04/26/i-blue-it/.
Souza BR. Pressões respiratórias estáticas máximas. J Pneumol. 2002;28(Suppl 3):155-165.
Lima LP. Mensuração das pressões respiratórias máximas com equipamentos analógico e digital. In: Congresso de Iniciação Científica; 2007.
Azevedo SI, Silva CM, Martins MN, Guimarães MHS, Pessoa SBM. Valores de referência brasileiros para as pressões respiratórias máximas: uma revisão de literatura. ASSOBRAFIR Ciênc. 2017.
Rodrigues F, Bárbara C. Pressões respiratórias máximas: proposta de um protocolo de procedimentos. Rev Port Pneumol. 2000;6:297.
Melo JBDC, Campos TF, Freitas DA, Borja RO, Nascimento RA, Mendonça KMPP. Comparison between maximal respiratory pressures obtained from digital and analog manovacuometer in healthy children. J Respir Cardiovasc Phys Ther. 2012;1(2):44-50.
Cordeiro, FH. Avaliação da concordância entre as medidas da pressão inspiratória máxima em manovacuômetros analógico e digitais no serviço de terapia intensiva do hospital naval marcílio dias. [dissertação]. Niterói (RJ): Universidade Federal Fluminense; 2022.
Montemezzo D, Velloso M, Britto RR, Perreira FV. Pressões respiratórias máximas: equipamentos e procedimentos usados por fisioterapeutas brasileiros. Fisioter Pesq. 2009.
Melo LTA, Monteiro SK, Menezes SRVK. Correlação das pressões musculares respiratórias do manovacuômetro e i blue it em crianças: um estudo piloto. [tese]. Natal (RN): Universidade Federal do Rio Grande do Norte; 2022.
Pereira AV, Eldebrando L, Silva EH, Eichinger FLF, Noveletto F, Soares VA. Biomedical system to evaluate pulmonary function in patients with post-stroke hemiparesis. Fisioter Mov. 2020. doi:10.1590/1980-5918.033.AO38.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Débora Valente de Aguiar , Gabriela Leite, Jenifer Cristina Perrut da Silva , Rafaela Dutra Francisco, Fabiane Maria Klitzke dos Santos , Marcelo da Silva Hounsell, Fabrício Noveletto , Helton Eckermann da Silva (Autor)

This work is licensed under a Creative Commons Attribution 4.0 International License.
Autores que publicam nesta revista concordam com os seguintes termos:
Autores mantém os direitos autorais e concedem à revista o direito de primeira publicação, com o trabalho simultaneamente licenciado sob a Licença Creative Commons Attribution 4.0 que permite o compartilhamento do trabalho com reconhecimento da autoria e publicação inicial nesta revista.
Autores têm autorização para distribuição não-exclusiva da versão do trabalho publicada nesta revista (ex.: publicar em repositório institucional ou como capítulo de livro), com reconhecimento de autoria e publicação inicial nesta revista.